Magnetic sensor MIP2.54
Pole Pitch | 2.54 mm |
Resolution | 48.000, 24.000, 12.000, 9.600, 6.000, 4.800, 3.000, 2.400, 1.200, 600 dpi |
Accuracy | ± 13 µm |
Measuring length | depending on magnetic tape |
Interface | Line Driver, Push-Pull |
Zum Konfigurieren dieses Artikels benutzen Sie bitte den Bestellschlüssel:
Any questions?

Your Contact
Christian Willmann
c.willmann@willtec.de
+49 (0)7665 - 93465-17
Download brochure
- Order number: MIP2.54
- Magnetic sensor for linear and angular contactless reading
- Very small size 36 x 11 x 13,5 mm to allow installation in narrow spaces
- Housing made of die-cast metallic material
- Resolutions up to 48.000 dpi
- Status indication through LED RGBW
- Flexible cable for axial or radial connection
- Easy and fast mounting of the entire measuring system, with wide alignment tolerances
- Distance sensor/magnetic scale up to 0.3 mm
- Speed up to 56,2 m/s (at 600 dpi)
- IP-Rating IP67
- Option: cleaning wipers to remove dirt deposits from the magnetic scale
Technical data
Pole pitch |
2.54+2.54 mm |
||||
Reference indexes |
C = constant step (every 5.08 mm) R = positioned on the magnetic scale |
||||
Resolution [dpi] |
48.000 |
24.000 |
12.000 |
9.600 |
6.000 |
4.800 |
3.000 |
2.400 |
1.200 |
600 |
|
Accuracy grade |
±13 μm 1) |
||||
Interpolation error (SDE) |
± 3.5 μm 2) |
||||
Unidirectional repeatability |
± 0.8 μm 2) |
||||
Hysteresis |
3 μm 2) |
||||
A, B and I0 output signals |
Line Driver / Push-Pull |
||||
Vibration resistance (EN 60068-2-6) |
300 m/s2 [55 … 2000 Hz] |
||||
Shock resistance (EN 60068-2-27) |
1000 m/s2 [11 ms] |
||||
Protection class (EN 60529) |
IP 67 |
||||
Operating temperature |
-20 °C … 75 °C |
||||
Storage temperature |
-40 °C … 80 °C |
||||
Relative humidity |
100% |
||||
Power supply |
5 to 24 VDC ±10% 3) |
||||
Current consumption without load |
40 mAMAX |
||||
Current consumption with load |
100 mAMAX (with 5 V and R = 120 Ω) 80 mAMAX (with 24 V and R = 1.2 kΩ) |
||||
Electrical connections |
8-wire connecting cable, open cable end (standard) M12-connector (plug); 8-pin (optional) Other connections on request |
||||
Electrical protections |
inversion of polarity and short circuits |
||||
Weight |
20 g |
1) The declared accuracy grade of ± X μm is referred to a measuring length of 1 m.
2) The error declared is subject to the respect of the alignment tolerances.